Multicore covers libraries for effects, domains and concurrent programming.
November 2026/Multicore
The most visible change this month is Eio's work on Windows filesystem support. A pull request adds resolution of symlinks, junctions, and reparse points to Eio's file operations, which would let tools like Forester walk directory trees that contain links on Windows without leaving the sandbox. The change is still in progress as of the reporting weeks. (Source)
Unix-domain sockets got a cluster of practical fixes. ocaml-uring shipped version 2.15.1 on 6 November, correcting a bug where sending a message to a Unix-domain address passed the wrong buffer size and caused the call to fail. On the Eio side, a second listener that fails to bind to a Unix path no longer deletes the first listener's socket file, and closing a Unix-domain socket now removes its file immediately rather than waiting for the enclosing switch to finish. (Source, Source)
Two smaller but important fixes round out the period. A trailing slash on the final component of a sandboxed path could previously follow a symlink out of the sandbox boundary; a fix treats the path as if a dot were appended, matching Linux behaviour. Separately, when a switch encounters an error, the actual exception is now recorded before daemon fibers are cancelled, so error queries return the real cause instead of a generic cancellation message. (Source, Source)
W47.2026 · 16–22 Nov/Multicore
Eio, OCaml's async I/O library, releases version 1.7 with new APIs and corrected Windows path handling. Merged fixes in ocaml-uring, OCaml's io_uring interface, prevent a crash when a signal arrives during a wait and stop silent truncation of file paths.
Releases
Eio v1.7: Released 2026-11-16. The update adds APIs for partitioning a list of fibres, removing a hook from a switch, querying system information, setting a signal handler, and synchronising a directory entry.
Open issues
Saturn queue correctness:Saturn has an open report that is_full can return false on a full queue. A maintainer confirmed the diagnosis on 17 November and suggested a fix, but the issue remains unresolved. See #190.
Fixes
Eio Windows device paths: DOS device names such as NUL in unrestricted paths are now resolved correctly. This restores Filename.null and fixes a regression that affected Forester 6.0. See #995.
Eio Unix-domain connect: A temporary "would block" response from a full socket backlog is no longer treated as a connection in progress. The call now fails clearly instead of returning a socket that is not actually connected. See #981.
ocaml-uring signal handling: A signal arriving after a submission now interrupts the wait and returns None. Previously the signal was swallowed and triggered an assertion failure. See #179.
ocaml-uring path validation: Paths containing NUL bytes are now rejected rather than silently truncated. Path length is also treated as unsigned, avoiding misbehaviour with very long paths. See #172 and #176.